v4.3 [Mar 11, 2015]
Added support for CR6 Series dataloggers.
Added support for CRVW Series Vibrating Wire Recording Interfaces.
Added support for dragging and dropping files from Windows Explorer onto the File Control dialog.
Added support for modifying Station Status.
v4.2 [Feb 11, 2014]
- PC200W Enhancement - Added PakBus Encryption Key setting to the CR1000/CR3000/CR800 Series.
- PC200W Enhancement - Added the ability to view a file from File Control.
- PC200W Bug Fix - Changed default Beacon Interval to 0.
- PC200W Bug Fix - Time zone offset is now applied when finish is clicked as well as when the user sets the clock.
- PC200W Bug Fix - Trying to send an OS to a 2 Meg CR1000 now gives the correct error message.
- PC200W Bug Fix - Removed the Time of Fill column from the Station Status because the information was not always correct.
- PC200W Bug Fix - Fixed a bug when dealing with very large records.
- Short Cut Enhancement - Added a cache of the sensor files to speed loading.
- Short Cut Enhancement - Added Datalogger Step that combines the datalogger selection, scan rate selection, and CR9000X card selection.
- Short Cut Enhancement - When adding a sensor, if more than one of the selected sensor can be added, the choice of how many sensors to add is included as part of the sensor’s form rather than as a separate dialog box
- Short Cut Enhancement - When adding more than one sensor, a dialog box is available that allows you to input unique values for certain calibration and/or conversion factors (e.g., multiplier, offset, gage factor) for each sensor being measured.
- Short Cut Enhancement - Each sensor form now includes a wiring tab that shows the wiring for the sensor. This tab allows you to manually change the wiring location, if desired.
- Short Cut Enhancement - For some sensors that require an excitation voltage, the sensor form now includes parameters that allow you to calculate Sensors per Excitation Channel. (Exciting more than one sensor with an excitation channel is helpful when the sensors to be measured outnumber the available excitation channels.)
- Short Cut Enhancement - Added an SC115 checkbox to the Outputs screen to copy data to an SC115.
- Short Cut Enhancement - Added new or updated sensor files for the 27106T Wind Speed Sensor, the CS525 ISFET pH Probe, the CS650/655 Water Content Reflectometer, the CS506 Fuel Moisture Sensor, the NR-LITE2 Net Radiometer, the CNR4 Net Radiometer, a Quarter Bridge Strain Gage, Half Bridge Strain Gage, Full Bridge Strain Gage, the Geokon 4000/4050 Vibrating Wire Strain Gage, the Geokon 4100 Series Vibrating Wire Strain Gage, the Geokon 4420 Vibrating Wire Crackmeter, the Geokon 4500 Series Vibrating Wire Piezometer, Geo-Instruments Electrolevel Tiltmeter, VTI ECI-1 Embedded Corrosion Instrument, Modbus Master, Modbus Slave, BS-3 /OBS300 Turbidity Sensor, HC2S3 Temperature and Relative Humidity Sensor, OBS500 Smart Turbidity Meter (SDI-12), Device for Analog Input from SDM-AO4A, 52202 Rain Gauge (CSI), CMP3/CMP6/CMP11 Pyranometer, CS526/CS525 ISFET pH Probe, 020C Wind Direction Sensor, A100LK Wind Speed Sensor, 092 Barometric Pressure Sensor, 61302V Barometric Pressure Sensor, P2546A Wind Speed Sensor, 110PV Surface Temperature Probe, and a Wind Vane Installation Offset Correction (calculation)
- Short Cut Enhancement - Enhanced readability of Wiring Text.
- Short Cut Enhancement - Selected Sensors are now shown in a tree format and branches can be expanded or collapsed as needed.
- Short Cut Bug Fix - Fixed an issue where toggling the advanced outputs was not configuring the flags correctly.
- Short Cut Bug Fix - Fixed an issue where Short Cut would crash if the user attempted to delete a sensor that referenced a custom sensor file that no longer existed.
- Short Cut Bug Fix - Creating custom sensor files for multiplexers is no longer allowed.
- Short Cut Bug Fix - Fixed some translation issues.
- Short Cut Bug Fix - Fixed some issues in wiring diagram where wires were not being shown.
- Short Cut Bug Fix - Fixed an issue where a *4 attribute in a CR10X program caused and access violation.
- Short Cut Bug Fix - Fixed a problem where if you created a program for a CR10XTD/CR10XPB that utilized high res to final storage you would get three FSL field labels for that output instead of one.
- Short Cut Bug Fix - Fixed a problem where generating a CR10X program that used an AM25T would give an error when "differential voltages" was selected for the output type.
- View Enhancement - Added ability to import CSV files.
- View Enhancement - Added a search function to the main grid accessible using ctrl-f, or Edit/Find.
- View Enhancement - Added the record view dialog to address the requirements for displaying a status table record. The record view dialog will work for any CSI file type displayed in a grid.
- View Enhancement - Added cancel button to Selection Properties for line graph selections. Also added cancel buttons to the Graph Options screen. This change will change back the on-screen live changes.
...
It works with your AT&T mobile device to provide wireless Internet connectivity.